| Clin Shoulder Elb > Volume 28(2); 2025 > Article |
|
Author contributions
Conceptualization: AK, JAA. Data curation: MD, TP. Formal analysis: MD. Investigation: MD, AK. Methodology: Project administration: Writing – original draft: MD, TP, PB, MYF, WK. Writing – review & editing: JGH, JAA, AZK. All authors read and agreed to the published version of the manuscript.
Conflict of interest
AZK would like to disclose receiving support from Stryker and DePuy and serving as a paid presenter or speaker for Enovis. JAA would like to disclose royalties from a company or supplier disclosures: Osteocentric Technologies, Enovis, Zimmer-Biomet, Stryker, Globus Medical Inc. Stocks in: Shoulder Jam, Aevumed, OBERD, OTS Medical, Orthobullets, Atreon, Restore 3D. Research support from a company or supplier as a PI disclosures: Enovis, Arthrex. Royalties, financial or material support from publishers: Wolters Kluwer, Slack Orthopaedics, Elsevier. Board member/committee appointments for a society disclosures: American Shoulder and Elbow Society, Mid Atlantic Shoulder and Elbow Society, Shoulder 360, Pacira.
| Study | Methods |
Participant |
Implant |
Age (yr) |
Mean follow-up | Used system |
Adverse event |
|||
|---|---|---|---|---|---|---|---|---|---|---|
| PSI | SI | PSI | SI | PSI | SI | |||||
| Boekel et al. (2023) [19] | Randomized controlled trial | 24 | 23 | Reverse total shoulder arthroplasty | 69 | 70 | 2.0 yr | Image-derived instrumentation jigs | 2 Grade 1 scapular notching | 2 Grade 1 scapular notching |
| 1 Grade 2 scapular notching | 1 Anterior shoulder dislocation | |||||||||
| 1 Subacromial bursitis | ||||||||||
| Dasari et al. (2024) [20] | Randomized controlled trial | 19 | 17 | Anatomic total shoulder arthroplasty | 60 | 61 | 6.0 mo | Patient-specific drill guide | - | - |
| Elsheikh et al. (2022) [14] | Retrospective | 18 | 34 | Reverse total shoulder arthroplasty | 69 | 68 | 2.0 yr | Signature glenoid shoulder system | 1 Grade 1 scapular notching | 1 Grade 1 scapular notching |
| 1 Long baseplate screw | ||||||||||
| 1 Baseplate failure | ||||||||||
| Hendel et al. (2012) [21] | Randomized controlled trial | 15 | 16 | Anatomic total shoulder arthroplasty | - | - | 4.0 mo | Glenoid positioning system group | 1 Transient axillary nerve injury | - |
| Heylen et al. (2016) [22] | Prospective | 18 | 18 | Reverse and anatomic total shoulder arthroplasty | 71 | 71 | - | - | - | - |
| Hwang et al. (2023) [23] | Retrospective | 122 | 56 | Reverse total shoulder arthroplasty | 69 | 68 | 2.0 yr | 5D Glenoid Targeter; | 1 Periprosthetic fracture | 1 Periprosthetic fracture |
| Arthrex Inc. | 1 Deep vein thrombosis | |||||||||
| Kwak et al. (2022) [24] | Retrospective | 19 | 20 | Reverse total shoulder arthroplasty | 74 | 77 | - | 3D PSI; 3D Systems | 10 Scapular notching | 2 Scapular notching |
| Yelton et al. (2024) [25] | Retrospective | 22 | 23 | Reverse total shoulder arthroplasty | 70 | 74 | - | Stryker | - | - |
| Yung et al. (2023) [26] | Retrospective | 31 | 42 | Reverse total shoulder arthroplasty | 76 | 77 | 2.0 yr | - | 1 Shoulder dislocation | 1 Prosthetic joint infection |
| Study | Confounding bias | Selection bias | Classification bias | Bias due to deviation from interventions | Bias due to missing data | Bias in measurement of outcomes | Bias in selection of reported results | Results |
|---|---|---|---|---|---|---|---|---|
| Elsheikh et al. (2022) [14] | Moderate risk | Moderate risk | Low risk | Low risk | Low risk | Low risk | Low risk | Moderate risk |
| Heylen et al. (2016) [22] | Low risk | Low risk | Low risk | Low risk | Low risk | Low risk | Low risk | Low risk |
| Hwang et al. (2023) [23] | Low risk | Low risk | Low risk | Low risk | Low risk | Low risk | Low risk | Low risk |
| Kwak et al. (2022) [24] | Low risk | Low risk | Low risk | Low risk | Low risk | Low risk | Low risk | Low risk |
| Yelton et al. (2024) [25] | Low risk | Low risk | Low risk | Low risk | Low risk | Low risk | Low risk | Low risk |
| Yung et al. (2023) [26] | Low risk | Low risk | Low risk | Low risk | Moderate risk | Low risk | Low risk | Moderate risk |
Patient-specific instrumentation in shoulder arthroplasty: high tech, low yield?2025 June;28(2)

![]() |
![]() |