Does the polarity of radial head arthroplasty affect functional outcomes? A systematic review and meta-analysis
Article information
Abstract
Background
Radial head arthroplasty allows a high degree of customizability, and implant polarity has emerged as an important variable. The purpose of this meta-analysis was to evaluate differences in functional and clinical outcomes between patients receiving monopolar and bipolar radial head prosthetic implants.
Methods
A systematic review and meta-analysis were employed, and 65 articles were identified in three databases. Twelve articles contained non-English or insufficient text and were consequently excluded, and 20 others did not contain sufficient data or follow-up. The remaining 33 articles were qualitatively and quantitatively reviewed.
Results
In total, 33 populations were identified, with 809 unduplicated patients: 565 with monopolar and 244 with bipolar implants. In these respective patients, the mean follow-up was 40.2 and 56.9 months. Average Mayo Elbow Performance Score were 86.7 and 87.4 (P=0.80), respectively; average Disability of the Arm, Shoulder, and Hand scores were 17.9 and 14.7 (P=0.47), and average final flexion/extension arcs were 119.4° and 118.7° (P=0.48). Revision rates were 4.07% and 6.56%, while complication rates were 19.65% and 20.08% in the respective monopolar and bipolar patients. These increased relative risks associated with bipolar implants were not significant.
Conclusions
Radial head implant polarity does not appear to affect functional outcomes. While bipolar prosthetic design may increase the risks of revision and complications, the increases were not significant.
Level of evidence
IV.
INTRODUCTION
Recent trends and studies have suggested that radial head arthroplasty is a preferred option in treatment of comminuted radial head fractures not amenable to open reduction and internal fixation, and that it is superior to radial head resection [1]. When deciding arthroplasty options, surgeons may select monopolar or bipolar radial head arthroplasty. The polarity of this implant has emerged as an area of controversy [1-3], and there is currently little clarity as to which type may be superior. A monopolar radial head prosthesis is fixed between the head and the neck, while bipolar implants contain an articulating head/neck segment that permits greater biomechanical freedom. Both monopolar and bipolar implants have demonstrated the ability to restore valgus stability to the elbow in several biomechanical and clinical studies [2-5].
Bipolar radial head prostheses were first introduced by Judet in 1988, serving as an alternative to the original monopolar design [2-3,6]. Bipolar implants allow increased motion of the prosthetic radial head, theoretically enabling a more congruent association of the radiocapitellar joint. In addition, the increased articulation of the head has been proposed to decrease stress at the implant-bone interface [4,7]. However, several complications have been noted with bipolar designs, including aseptic loosening and, importantly, radiocapitellar instability [6,8-10]. A bipolar articulation may also lead to polyethylene or other mechanical wear between the head and neck of the prosthesis. Specifically, conflicting data have been found in bipolar implant use in patients with elbow dislocation [1].
The purpose of this meta-analysis is to evaluate differences in functional and clinical outcomes between patients receiving monopolar or bipolar radial head prosthetic implants. We hypothesized that patients who undergo radial head arthroplasty with a monopolar prosthesis would have significantly fewer complications, loosening, and instability events related to the articulating prosthesis irrespective of indication.
METHODS
A systematic review was performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Three authors conducted the search independently using PubMed, Embase, and Medline databases. The electronic search citation algorithm used was: (radial head) AND (arthroplasty) NOT (shoulder) NOT (knee) NOT (hip). Inclusion demanded full-text studies, written in English, with level I-IV evidence. All references were cross-referenced to ensure they had already been reviewed. The search resulted in 65 articles with no duplicates (43 PubMed, 22 Embase). Twelve studies were excluded as they were not in English or full text, and an additional 20 populations were excluded due to lack of appropriate data; some studies had duplicate data sets, others lacked the standard 24 months of mean follow-up, and others did not explicitly identify specific implant design (monopolar or bipolar). This left 33 studies to be included in this review.
All populations underwent radial head arthroplasty for a variety of indications. There were no requirements for rehabilitation for studies to be included. Populations were separated into monopolar and bipolar groups for further analysis. The variables collected from each study were year of publication, country, level of evidence, study design, inclusion period, number of patients, number of patients lost to follow-up, mean follow-up, mean age, numbers of men and women included, indication for surgery, type of fixation, material type used, modularity, number of revisions, revision rate, complications, and complication rate, as well as well-validated outcome measurements. These validated outcome measurements were the Mayo Elbow Performance Score (MEPS), the Disability of the Arm, Shoulder, and Hand (DASH) score, and the mean Flexion/Extension arc.
Continuous variables—MEPS, DASH score, and flexion/extension arc—were reported as standardized mean differences when available. Dichotomous variables—revision and complication rates—were reported using risk ratios. With the high degree of heterogeneity among the data sets used, a random effects model was used. We assigned statistical significance to P-value <0.05.
RESULTS
A total of 809 patients (monopolar=565, bipolar=244) was identified in the 33 populations. Mean follow-up was 45.8 months (monopolar=40.2, bipolar=56.9). Most populations (54.5%) reported “fractures” as the indication for radial head arthroplasty. Most studied populations were retrospective (87.8%) (Tables 1 and 2) [8,10-39].
Outcomes were described using the following validated metrics: DASH score, MEPS, and flexion-extension arcs (Table 3). MEPS was reported by 84.8% of the 33 populations (monopolar=86.3%, bipolar=81.8%). The total combined average of the MEPS was 86.9, and no statistically significant difference was found between the groups (monopolar=86.7, bipolar=87.4; 95% CI, –5.0 to 3.5; P=0.80). The DASH score was reported by fewer populations, in only 45.4% (monopolar=45.5%, bipolar=45.4%). There was no overall mean statistical difference reported between the two groups (overall=16.8, monopolar=17.9, bipolar=14.7; 95% CI, –3.8 to 10.2; P=0.47). All but three populations reported mean flexion-extension arc (overall=87.9%, monopolar=86.4%, bipolar=90.9%). No statistical difference in ROM arc was reported among the groups (overall=119.1, monopolar=119.4°, bipolar=118.7°; 95% CI, –8.5 to 9.8; P=0.48).
In addition to these functional metrics, revision rates and complications were also calculated (Table 3). An overall revision rate of 4.82% was found, with a monopolar rate of 4.07% and bipolar rate of 6.56%. While a 61% increased risk for revision was associated with bipolar implants, this increase was not significant (relative rate [RR]: monopolar=0.76, bipolar=1.31; 95% CI, 0.86 to 9.8; P=0.13). The complication rate of the combined populations was 19.78% (monopolar=19.65%, bipolar=20.08%), with a 2% not significantly increased risk with bipolar implants (RR monopolar=0.98, bipolar=1.02; 95% CI, 0.76 to 1.38; P=0.89). The most frequently reported complications of monopolar implants were ulnar nerve palsies, followed by stiffness and wound infection. For bipolar implants, the most commonly reported complications were ulnar nerve palsies, followed by heterotopic ossification and stiffness.
DISCUSSION
Radial head arthroplasty involves several procedural variables, including the design option of using a non-articulating, "mono-" or "unipolar" implant versus a jointed, “bipolar” implant. While some studies support bipolar prostheses [2,4,10,36], citing their more congruent, dynamic capitellar articulation, others report their heightened incidence of unique complications and suboptimal performance compared to monopolar [2,3,6,40-42]. The purpose of this study was to determine if any significant advantage is offered by either implant in terms of functional outcomes, revision, and complications. Our data suggest that there is not.
Several investigations support the apparent clinical equivalency of monopolar and bipolar prosthetic design. Rotini et al. [5] noted no differential superiority when comparing results functionally, clinically, and radiographically at 2 years of follow-up. Berschback et al. [19] found no significant difference in terms of motion, strength, pain, and functional outcome. Others [7,8,10,35,36] have noted satisfactory to promising outcomes in consistent case series of bipolar RHA prostheses over 2- to 9-year follow-up. Notably, Sershon et al. [43] have recently reported 16 bipolar arthroplasty cases with excellent 10-year results in terms of functional outcomes, range of motion, stability, and implant survivability.
However, some cadaveric investigations suggest challenges with the performance of bipolar articulation at the radiocapitellar joint. For example, Moon et al. [6] suggest a bipolar implant’s propensity for dislocation by demonstrating their lower force requirement before posterior subluxation compared to both monopolar prostheses and anatomic radial heads. These results correlate with those of Chanlalit [41,42], although their specimens were compromised by significant soft tissue dissection. Given these biomechanical findings, many surgeons are concerned about radiocapitellar instability and potential dislocation as a unique complication of the bipolar design [2]. The quality of lateral collateral ligament repair and soft tissue balancing is difficult to control in clinical studies. As a result, this point is a distinct limitation when attempting to differentiate superiority of one polarity design over another.
While indications for radial head arthroplasty may play a role in implant outcomes, a study from Antoni et al. [1] that investigated polarity in the setting of fracture dislocations found no differences in outcomes between those with terrible triad injuries, Monteggia type injuries, transolecranon dislocations, and divergent dislocations. They found no differences at over two years of follow-up of 18 patients treated with bipolar implants and 40 with monopolar implants for stability, complications, revision rates, range of motion, MEPS, and radiographic parameters. Their findings are similar to those of this study, further supporting some role of indications such as concurrent dislocation. They did observe a correlation between high implant positioning and postoperative instability (P=0.022) as well as the need for revision surgery (P=0.021) in both groups, suggesting that surgical technique may be the most important factor when addressing injuries. Our data support this, indicating that surgeon familiarity should be the deciding factor in the absence of observed implant outcome differences.
Limitations do exist in this study. Publication bias may have been introduced by using English-only, full-text articles. Selection bias may exist as some studies may have been unintentionally omitted during article collection. Heterogeneity in data reporting, technique, indications, and follow-up inevitably skews statistical calculations. Specifically, as several implant designs limit variability in fixation technique, polarity, and component material, these variables may inherently confound one another.
CONCLUSIONS
In conclusion, our meta-analysis did not demonstrate significant differences in functional outcomes, complication rates, and revision rates between monopolar and bipolar radial head arthroplasty irrespective of indication. A multicenter prospective control trial is needed to conclude if there are true differences between these implant types.
Notes
Author contributions
Conceptualization: SDD. Data curation: KA, AM. Investigation: KA, SDD. Methodology: KA, AM, SDD.
Supervision: SDD. Validation: SDD. Writing – original draft: KA. Writing – review & editing: AM, SDD.
Conflict of interest
None.
Funding
None.
Data availability
None.
Acknowledgments
None.